What Is the MQ-135? Air-Quality Gas Sensor and Uses

November 21, 2026 4 min read
Quick answer

The MQ-135 is a gas sensor used for air-quality measurement. It is sensitive to pollutants like ammonia, benzene, smoke and CO2; it gives an analog (AO) and a digital threshold (DO) output and runs from 5 V. Accurate reading needs warm-up/stabilization and calibration; without calibration it gives only relative change and is cross-sensitive to gases (not selective).

The MQ-135 is a gas sensor used for air-quality measurement. It is sensitive to various pollutant gases such as ammonia (NH3), benzene, smoke and CO2; it gives an analog and a digital output. For the concept, see what is a gas sensor.

What is the MQ-135 used for?

Ambient air-quality monitoring, indoor pollution alerts, smart home and greenhouses. Its module gives both an analog (AO) and a threshold-set digital (DO) output; it is in the same MQ family as the MQ-2 (flammable gas/smoke).

Specifications

ParameterValue
TypeSemiconductor gas sensor (air quality)
TargetNH3, benzene, smoke, CO2, etc.
OutputAnalog (AO) + digital threshold (DO)
Supply5 V (built-in heater)

Watch out

Because it has a built-in heater, a warm-up/stabilization time is needed for accurate reading (long on first use). Calibration is a must for absolute PPM measurement; without it the sensor gives only relative change/threshold alerts. It is cross-sensitive to different gases (not selective); for life safety (a detector) a certified device must be used.

Equivalents

  • MQ-2: flammable gas/smoke (LPG, methane).
  • MQ-7: carbon monoxide (CO).
  • CCS811 / SGP30: digital (I²C) air-quality (eVOC/CO2) sensors.

Find it in our catalog

Use the MQ-135 search.

Frequently Asked Questions

What is the MQ-135?+
The MQ-135 is a gas sensor used for air-quality measurement. It is sensitive to pollutants like ammonia, benzene, smoke and CO2; it gives an analog (AO) and a digital threshold (DO) output. It runs from 5 V and has a built-in heater.
Does the MQ-135 measure PPM?+
Calibration is a must for absolute PPM. Without calibration the sensor gives only relative change and threshold alerts; it is also cross-sensitive to different gases, so it is not selective.
Why does the MQ-135 need a warm-up time?+
Its built-in heater brings the sensor surface up to operating temperature. A few minutes of warm-up (a much longer stabilization on first use) is needed for accurate reading.
What is an MQ-135 equivalent?+
The MQ-2 for flammable gas/smoke; the MQ-7 for CO; the CCS811/SGP30 for digital air quality.