Skip to main content
PartAndStock
Blog

What Is the MAX30102? Heart-Rate/SpO2 Optical Sensor and Uses

November 22, 2026 4 min read
Quick answer

The MAX30102 is an I²C optical sensor (pulse oximeter) to estimate heart rate and blood oxygen (SpO2). It has red+infrared LEDs and a photodetector; it measures blood volume change (PPG) from light reflected off skin. It is NOT a medical device; readings are estimates and cannot be used for clinical diagnosis. Accurate reading needs good skin contact and algorithms.

The MAX30102 is an I²C optical sensor (pulse oximeter) designed to measure heart rate and blood oxygen (SpO2). It contains red and infrared LEDs plus a photodetector. For the concept, see what is a sensor.

What is the MAX30102 used for?

Wearables that estimate heart rate and SpO2, fitness bands and health projects. By measuring light reflected through a finger/wrist it senses blood volume change (PPG); processing yields heart rate/SpO2.

Specifications

ParameterValue
TypeOptical heart-rate/SpO2 sensor (PPG)
LEDsRed + infrared
InterfaceI²C
Supply~1.8 V core + ~3.3–5 V LED (by module)

Watch out

It is not a medical device; the readings are estimates and cannot be used for clinical diagnosis. For accurate reading the sensor needs good skin contact, a stable position and blocked light leakage. Filtering/algorithms are a must to turn the raw data into heart rate/SpO2. The MAX30100 is an older, different relative.

Equivalents

  • MAX30100: an older heart-rate/SpO2 sensor.
  • MAX30105: a variant with an extra green LED (particle/sensing).
  • MAX86141: a more advanced optical biosensor.

Find it in our catalog

Use the MAX30102 search.

Frequently Asked Questions

What is the MAX30102?+
The MAX30102 is an I²C optical sensor (pulse oximeter) to estimate heart rate and blood oxygen (SpO2). It has red+infrared LEDs and a photodetector; it measures the PPG signal.
Does the MAX30102 make medical measurements?+
No; it is not a medical device. The readings are estimates and cannot be used for clinical diagnosis. It suits fitness/hobby projects; accurate reading needs good skin contact and an algorithm.
How does the MAX30102 work?+
It shines light onto the skin with the LEDs and measures the reflected/transmitted light with the photodetector. Blood volume change (PPG) modulates the light; this signal is filtered and processed to estimate heart rate and SpO2.
What is a MAX30102 equivalent?+
The older MAX30100; the MAX30105 with a green LED; the advanced MAX86141.