Skip to main content
PartAndStock
Blog

What Is the BT139? Triac (TRIAC): Pinout and Uses

October 30, 2026 4 min read
Quick answer

The BT139 is a 16 A-class triac (TRIAC); a power switch that can conduct both half-cycles of AC. It is used to switch AC mains loads (lamps/heaters/motors) and in dimmer circuits. Pinout TO-220: MT1 – MT2 – Gate (tab = MT2). When driven from an MCU it is isolated with a triac-driver optocoupler like the MOC3021; inductive loads need a snubber (RC).

The BT139 is a 16 A-class triac (TRIAC). A triac is a power switch that can conduct both half-cycles of AC; a small current into its gate turns it on and it conducts until the current reaches zero. For the concept, see what is a triac.

What is the BT139 used for?

Switching AC mains loads (lamps, heaters, motors) and dimmer circuits. When driven from a microcontroller it is usually isolated with a triac-driver optocoupler such as the MOC3021 for safety.

Pinout (TO-220)

Front face forward, left to right: MT1 – MT2 – Gate. The metal tab is connected to MT2.

PinFunction
1MT1 (main terminal 1)
2MT2 (main terminal 2)
3Gate

Watch out: gate triggering and snubber

The triac gate is triggered with a suitable resistor (referenced to MT2 where needed). With inductive loads (motors/transformers) a snubber (RC) circuit is usually added to prevent premature turn-off. Because it works at mains voltage, isolation and safety are critical.

Equivalents

  • BT136/BT137/BT138/BT139: same family, different current (4/8/12/16 A).
  • BTA16: a triac with an insulated tab.
  • MOC3021: a triac-driver optocoupler (isolated trigger).

Find it in our catalog

Use the BT139 search.

Frequently Asked Questions

What is the BT139?+
The BT139 is a 16 A-class triac (TRIAC); a power switch that can conduct both half-cycles of AC. It is used for AC load switching and dimmer circuits (TO-220, 600 V class).
What is the BT139 pinout?+
TO-220, front face forward, left to right MT1 – MT2 – Gate. The metal tab is connected to MT2.
How is the BT139 triggered?+
A small current is fed to the gate through a suitable resistor; the triac turns on and conducts until the current reaches zero. When driving from an MCU, isolate it with a triac-driver optocoupler like the MOC3021.
Does the BT139 need a snubber?+
With inductive loads (motors/transformers) a snubber (RC) circuit is usually added to prevent premature turn-off/instability.
What is an equivalent to the BT139?+
Different-current BT136/137/138/139 in the same family; the insulated-tab BTA16; the MOC3021 optocoupler for isolated triggering.